#SEP times calculated by idsep
#Experiment: GOES-11
#Flux type: integral
#Energy channel: 700.0 - -1
#Selected options: ['']
#Searched date range: 2003-06-01 to 2011-03-01
#User applied an initial cut of 10.0, initial averaging window of 150 days, final threshold with a sliding window of 5 days
#The percentage of points in the sliding window that must be background was 0.4
#Threshold defined as mean background + 3 x sigma
#SEPs were identified when 0 points  exceeded threshold, allowing up to 0 points to be missed. The SEP event ended after 0 were below threshold (dwell time).
#Start Time    End Time
2003-10-29 21:25:00 2003-10-30 08:15:00
2003-11-04 19:50:00 2003-11-27 23:45:00
2005-01-20 06:50:00 2005-01-21 07:00:00
2006-12-13 03:00:00 2006-12-13 18:00:00